Test Code LAB9644 IA2 Autoantibodies
Additional Codes
Mayo Test ID |
---|
FIAAB |
Reporting Name
IA-2 AutoantibodiesPerforming Laboratory
Esoterix EndocrinologySpecimen sent thru Mayo Medical Laboratory to Esoterix Endorcrinology
Specimen Type
SerumSpecimen Required
Collection Container/Tube:
Preferred: Serum gel
Acceptable: Red top
Submission Container/tube: Plastic vial
Specimen Volume: 1 mL
Collection Instructions:
1. Centrifuge and aliquot 1 mL of serum into a plastic vial.
2. Freeze immediately after separation and send frozen.
ATTENTION: Total whole blood collection volume to be sent to lab in a Gold SST gel tube is 2.0 mL (minimum 1.0 mL).
NOTE: Order will be cancelled by lab and re-ordered as a Miscellaneous Lab Test until the new Mayo test can be updated in SLCH LIS system.
Specimen Minimum Volume
0.5 mL (Note: Minimum volume does not allow for repeat analysis)
Specimen Stability Information
Specimen Type | Temperature | Time |
---|---|---|
Serum | Frozen (preferred) | 107 days |
Ambient | 72 hours | |
Refrigerated | 72 hours |
Method Name
Enzyme-linked Immunosorbent Assay (ELISA)
Reference Values
Negative: <7.5 U/mL
Positive: ≥ 7.5 U/mL
Day(s) Performed
Varies
Report Available
7 to 14 daysCPT Code Information
86341
LOINC Code Information
Test ID | Test Order Name | Order LOINC Value |
---|---|---|
FIAAB | IA-2 Autoantibodies | 31209-0 |
Result ID | Test Result Name | Result LOINC Value |
---|---|---|
FIAAB | IA-2 Autoantibodies | 31209-0 |