Test Code LAB7715 Itraconazole
Additional Codes
Eurofins-Viracor Test ID |
---|
2810 |
Performing Laboratory
St. Louis Children's Hospital Sendouts to Eurofins-Viracor
Specimen Requirements
Patient Preparation: None
Container/Tube
Preferred/Acceptable: Plain red-top tube
Collection Volume: 2.0 mL (minimum 1.0 mL)
Submission Container/Tube: If specimen is coming from outside facility aliquot processed sample into a plastic vial for transport (labeling with specimen type).
Special Instructions: Trough levels should be collected 30-60 minutes before the next dose.
Sample Rejection
Mislabeled or unlabeled specimens
Specimens collected in gel tubes
Logistics
Test Availability: Monday-Sunday
Test set-up: Monday-Saturday
Turnaround Time: 1-2 days; results are available 8-12 hours from receipt in perfoming laboratory
Reference Values
Reference Interval (target therapeutic range): Result values must be summed for itraconazole and hydroxyitraconazole to determine the active circulating concentration.
Itraconazole (localized infection): | >0.5 mcg/mL |
Itraconazole (systemic infection): | >1.0 mcg/mL |
Critical Values: None established
Methodology
Liquid Chromatography/Tandem Mass Spectrometry (LC-MS/MS)
Limitations
- Assay range: 0.1-10.0 mcg/mL
Additional Information
FOR SLCH CORE LABORATORY USE ONLY
Lab Processing Instructions: Allow specimen to clot for 30-60 minutes then centrifuge to separate. Aliquot sample into a sterile, leak-proof screw-capped plastic vial for transport.
Processed Volume: 1.0 mL (minimum 0.5 mL) serum
Transport Temperature: Ambient
Analyte Stability:
Specimen Type | Temperature | Time |
---|---|---|
Whole Blood (unprocessed) | Ambient | NA |
Plasma/Serum (processed) | Refrigerated | 14 days |
Ambient (preferred) | 14 days | |
Frozen | 30 days |
Ship Monday through Friday. Friday shipments must be labeled for Saturday delivery. A Eurofins-Viracor test requistion form must accompany each specimen.
Ship specimens FedEx Priority Overnight to:
Eurofins Viracor, 18000 W 99th St. Ste, #10, Lenexa, KS 66219
Test Classification and CPT Code
80299
Test Classification: This test was developed and its performance characteristics determined by Eurofins Viracor. It has not been cleared or approved by the U.S. Food and Drug Administration
LOINC
10989-2
Last Reviewed
08/2025