Sign in →

Test Code LAB6649 Circulating Immune Complex, C1q Binding

Additional Codes

Mayo Test ID
FCQBA

Reporting Name

CIC, C1q Binding

Performing Laboratory

ARUP Laboratories
St. Louis Children's Test Catalog Note:

Specimen sent thru Mayo Medical Laboratory to ARUP Laboratories

Specimen Type

Serum


Specimen Required


Collection Container/Tube: Red top or serum gel

Submission Container/Tube: Plastic vial

Specimen Volume: 1 mL serum

Collection Instructions:

1. Allow complete clotting of red blood cells (up to 1 hour).

2. Within 30 minutes after clotting is complete, centrifuge and aliquot serum into a plastic vial.

3. Freeze immediately.

4. Send frozen.

Note: Critical frozen. Separate specimens must be submitted when multiple tests are ordered.


St. Louis Children's Test Catalog Note:

ATTENTION: Whole blood collection volume to be sent to lab in a Red-top or Gold SST gel tube is 2.0 mL (minimum 0.6 mL)

Specimen Minimum Volume

Serum: 0.3 mL

Specimen Stability Information

Specimen Type Temperature Time
Serum Frozen 14 days

Reference Values

Less than or equal to 3.9 ug Eq/mL

Day(s) Performed

Saturday, Monday, and Thursday

CPT Code Information

86332

LOINC Code Information

Test ID Test Order Name Order LOINC Value
FCQBA CIC, C1q Binding 27831-7

 

Result ID Test Result Name Result LOINC Value
Z2636 CIC, C1q Binding 27831-7

Report Available

4 to 15 days

Reject Due To

Gross hemolysis: Reject
Thawing: Cold reject; Warm reject
Non-frozen specimen Reject

Method Name

Semi-Quantitative Enzyme-Linked Immunosorbent Assay

Useful For

Detecting circulating immune complexes