Test Code LAB5028 Amikacin Level, Peak
Performing Laboratory
St. Louis Children's Hospital - Chemistry
Specimen Requirements
Patient Preparation: None
Container/Tube
Preferred: Mint green-top Lithium Heparin (MNTGRN LiHep) tube
Acceptable: Lavender-top (EDTA) tube or Plain red-top tube
Collection Volume: 2.0 mL (minimum 1.0 mL)
Submission Container/Tube: If specimen is coming from outside facility and collected in a microtainer, Lavender-top (EDTA) tube, or plain red-top tube aliquot processed sample into a plastic vial for transport (labeling with specimen type).
Special Instructions: Send to lab promptly.
Sample Rejection
Mislabeled or unlabeled specimens
Logistics
Test Availability: Monday-Sunday
Cut-off time: None; performed as received
Turnaround Time: Same day; 2 hours from receipt in performing lab
Reference Values
Therapeutic Range: 10.0-35.0 mcg/mL
Critical Values: None established
Methodology
Immunoassay (Kinetic interaction of microparticles in solution (KIMS) as measured by changes in light transmission).
Limitations
NA
Additional Information
FOR SLCH CORE LABORATORY USE ONLY
Lab Processing instructions: Centrifuge specimen to separate. If specimen is collected in a plain, red-top or Lavender-top (EDTA) tube, aliquot sample into a Roche false-bottom tube for testing (labeling with specimen type).
Processed Volume: 0.3 mL plasma/serum
Analyte Stability:
Specimen Type | Temperature | Time |
---|---|---|
Whole Blood (unprocessed) | Ambient | 8 hours |
Plasma/Serum (processed) | Refrigerated (preferred) | 2 days |
Ambient | 8 hours | |
Frozen | 4 weeks |
Test Classification and CPT Coding
80150
LOINC
3319-1
Last Reviewed